cvelist/2023/29xxx/CVE-2023-29177.json
2023-11-14 19:00:37 +00:00

159 lines
6.9 KiB
JSON

{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2023-29177",
"ASSIGNER": "psirt@fortinet.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer copy without checking size of input ('classic buffer overflow') vulnerabilities [CWE-120] in FortiADC version 7.2.0 and before 7.1.2 & FortiDDoS-F version 6.5.0 and before 6.4.1 allows a privileged attacker to execute arbitrary code or commands via specifically crafted CLI requests."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Execute unauthorized code or commands",
"cweId": "CWE-120"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Fortinet",
"product": {
"product_data": [
{
"product_name": "FortiDDoS-F",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "6.5.0"
},
{
"version_affected": "<=",
"version_name": "6.4.0",
"version_value": "6.4.1"
},
{
"version_affected": "<=",
"version_name": "6.3.0",
"version_value": "6.3.4"
},
{
"version_affected": "<=",
"version_name": "6.2.0",
"version_value": "6.2.3"
},
{
"version_affected": "<=",
"version_name": "6.1.0",
"version_value": "6.1.4"
}
]
}
},
{
"product_name": "FortiADC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "7.2.0"
},
{
"version_affected": "<=",
"version_name": "7.1.0",
"version_value": "7.1.2"
},
{
"version_affected": "<=",
"version_name": "7.0.0",
"version_value": "7.0.5"
},
{
"version_affected": "<=",
"version_name": "6.2.0",
"version_value": "6.2.6"
},
{
"version_affected": "<=",
"version_name": "6.1.0",
"version_value": "6.1.6"
},
{
"version_affected": "<=",
"version_name": "6.0.0",
"version_value": "6.0.4"
},
{
"version_affected": "<=",
"version_name": "5.4.0",
"version_value": "5.4.5"
},
{
"version_affected": "<=",
"version_name": "5.3.0",
"version_value": "5.3.7"
},
{
"version_affected": "<=",
"version_name": "5.2.0",
"version_value": "5.2.8"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://fortiguard.com/psirt/FG-IR-23-064",
"refsource": "MISC",
"name": "https://fortiguard.com/psirt/FG-IR-23-064"
}
]
},
"solution": [
{
"lang": "en",
"value": "Please upgrade to FortiDDoS-F version 6.5.1 or above \nPlease upgrade to FortiDDoS-F version 6.4.2 or above \nPlease upgrade to FortiADC version 7.2.1 or above \nPlease upgrade to FortiADC version 7.1.3 or above \n"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:F/RL:O/RC:C"
}
]
}
}