"value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write",
"cweId": "CWE-787"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "APOGEE PXC Compact (BACnet)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V3.5.5"
}
]
}
},
{
"product_name": "APOGEE PXC Compact (P2 Ethernet)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V2.8.20"
}
]
}
},
{
"product_name": "APOGEE PXC Modular (BACnet)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V3.5.5"
}
]
}
},
{
"product_name": "APOGEE PXC Modular (P2 Ethernet)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V2.8.20"
}
]
}
},
{
"product_name": "Nucleus NET",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V5.2"
}
]
}
},
{
"product_name": "Nucleus Source Code",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Versions including affected DNS modules"
}
]
}
},
{
"product_name": "TALON TC Compact (BACnet)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V3.5.5"
}
]
}
},
{
"product_name": "TALON TC Modular (BACnet)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V3.5.5"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf",
"refsource": "MISC",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf",
"refsource": "MISC",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
}
]
},
"impact": {
"cvss": [
{
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"baseScore": 8.1,
"baseSeverity": "HIGH"
}
]
}
}