"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-26997",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "Solid Edge SE2020",
"version": {
"version_data": [
{
"version_value": "All versions < SE2020MP13"
}
]
}
},
{
"product_name": "Solid Edge SE2020",
"version": {
"version_data": [
{
"version_value": "All versions < SE2020MP14"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions < SE2021MP4"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-822: Untrusted Pointer Dereference"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"refsource": "MISC",
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",