"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2023-0103",
"ASSIGNER": "ics-cert@hq.dhs.gov",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-788 Access of Memory Location After End of Buffer",
"cweId": "CWE-788"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "LS Electric",
"product": {
"product_data": [
{
"product_name": "XBC-DN32U",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Operating System Version 01.80"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02",
"refsource": "MISC",
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"
}
]
},
"generator": {
"engine": "VINCE 2.0.6",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2023-0103"
},
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<p>LS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: </p><ul><li>Restrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the \u201cHost Table\u201d option in the configuration window of the PLC.</li></ul>"
}
],
"value": "\nLS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: \n\n * Restrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the \u201cHost Table\u201d option in the configuration window of the PLC.\n\n\n"
}
],
"credits": [
{
"lang": "en",
"value": "HeeA Go of Dankook University reported these vulnerabilities"
}
],
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
]
}
}