mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-08-04 08:44:25 +00:00
91 lines
3.5 KiB
JSON
91 lines
3.5 KiB
JSON
{
|
|
"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2022-43398",
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-384: Session Fixation",
|
|
"cweId": "CWE-384"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Siemens",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "POWER METER SICAM Q100",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V2.50"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V2.50"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V2.50"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V2.50"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
|
|
}
|
|
]
|
|
},
|
|
"impact": {
|
|
"cvss": [
|
|
{
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
]
|
|
}
|
|
} |