"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2022-31805",
"ASSIGNER": "info@cert.vde.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-523 Unprotected Transport of Credentials",
"cweId": "CWE-523"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "CODESYS",
"product": {
"product_data": [
{
"product_name": "CODESYS Development System",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V2",
"version_value": "V2.3.9.69"
},
{
"version_affected": "<",
"version_name": "V3",
"version_value": "V3.5.18.30"
}
]
}
},
{
"product_name": "CODESYS Gateway Client",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V2",
"version_value": "V2.3.9.38"
}
]
}
},
{
"product_name": "CODESYS Gateway Server",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V2",
"version_value": "V2.3.9.38"
}
]
}
},
{
"product_name": "CODESYS Web server",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V1",
"version_value": " V1.1.9.23"
}
]
}
},
{
"product_name": "CODESYS SP Realtime NT",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V2",
"version_value": "V2.3.7.30"
}
]
}
},
{
"product_name": "CODESYS PLCWinNT",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V2",
"version_value": "V2.4.7.57"
}
]
}
},
{
"product_name": "CODESYS Runtime Toolkit 32 bit full",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V2",
"version_value": "V2.4.7.57"
}
]
}
},
{
"product_name": "CODESYS Edge Gateway for Windows",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V3",
"version_value": "V3.5.18.30"
}
]
}
},
{
"product_name": "CODESYS HMI (SL)",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V3",
"version_value": "V3.5.18.30"
}
]
}
},
{
"product_name": "CODESYS OPC DA Server SL",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V3",
"version_value": "V3.5.18.30"
}
]
}
},
{
"product_name": "CODESYS PLCHandler",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V3",
"version_value": "V3.5.18.30"
}
]
}
},
{
"product_name": "CODESYS Gateway",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "V3",
"version_value": "V3.5.18.30"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17140&token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c&download=",
"refsource": "MISC",
"name": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17140&token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c&download="
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"source": {
"defect": [
"CERT@VDE#",
"64140"
],
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
]
}
}