"CVE_data_meta": {
"ASSIGNER": "sirt@juniper.net",
"DATE_PUBLIC": "2019-10-09T16:00:00.000Z",
"ID": "CVE-2019-0074",
"STATE": "PUBLIC",
"TITLE": "Junos OS: NFX150 Series, QFX10K Series, EX9200 Series, MX Series, PTX Series: Path traversal vulnerability in NFX150 and NG-RE leads to information disclosure."
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Junos OS",
"version": {
"version_data": [
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "15.1F",
"version_value": "15.1F6-S12"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "!",
"version_name": "15.1",
"version_value": "15.1"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": ">=",
"version_name": "16.1",
"version_value": "16.1R6"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "16.1",
"version_value": "16.1R6-S6, 16.1R7-S3"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "!",
"version_name": "16.2 ",
"version_value": "16.2"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "17.1",
"version_value": "17.1R3"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": ">=",
"version_name": "17.2",
"version_value": "17.2R1-S3, 17.2R3"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "17.2",
"version_value": "17.2R3-S1"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": ">=",
"version_name": "17.3",
"version_value": "17.3R1-S1, 17.3R2"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "17.3",
"version_value": "17.3R3-S3"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": ">=",
"version_name": "17.4",
"version_value": "17.4R1"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "17.4",
"version_value": "17.4R1-S6, 17.4R2-S2, 17.4R3"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "18.1",
"version_value": "18.1R2-S4, 18.1R3-S3"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "18.2",
"version_value": "18.2R2"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "18.2X75",
"version_value": "18.2X75-D40"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "18.3",
"version_value": "18.3R1-S2, 18.3R2"
},
{
"platform": "NFX150, QFX10K, EX9200, MX, and PTX Series with NG-RE",
"version_affected": "<",
"version_name": "18.4",
"version_value": "18.4R1-S1, 18.4R2"
}
]
}
}
]
},
"vendor_name": "Juniper Networks"
}
]
}
},
"configuration": [
{
"lang": "eng",
"value": "To identify whether the device has NG-RE with vmhost, customer can run the following command:\n > show vmhost status\n Compute cluster: rainier-re-cc\n Compute Node: rainier-re-cn, Online\nIf the \"show vmhost status\" is not supported, then the device does not have NG-RE with vmhost."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A path traversal vulnerability in NFX150 Series and QFX10K Series, EX9200 Series, MX Series and PTX Series devices with Next-Generation Routing Engine (NG-RE) allows a local authenticated user to read sensitive system files. This issue only affects NFX150 Series and QFX10K Series, EX9200 Series, MX Series and PTX Series with Next-Generation Routing Engine (NG-RE) which uses vmhost. This issue affects Juniper Networks Junos OS on NFX150 Series and QFX10K, EX9200 Series, MX Series and PTX Series with NG-RE and vmhost: 15.1F versions prior to 15.1F6-S12 16.1 versions starting from 16.1R6 and later releases, including the Service Releases, prior to 16.1R6-S6, 16.1R7-S3; 17.1 versions prior to 17.1R3; 17.2 versions starting from 17.2R1-S3, 17.2R3 and later releases, including the Service Releases, prior to 17.2R3-S1; 17.3 versions starting from 17.3R1-S1, 17.3R2 and later releases, including the Service Releases, prior to 17.3R3-S3; 17.4 versions starting from 17.4R1 and later releases, including the Service Releases, prior to 17.4R1-S6, 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R2-S4, 18.1R3-S3; 18.2 versions prior to 18.2R2; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R1-S2, 18.3R2; 18.4 versions prior to 18.4R1-S1, 18.4R2. This issue does not affect: Juniper Networks Junos OS 15.1 and 16.2."
}
]
},
"exploit": [
{
"lang": "eng",
"value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
}
],
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "privilege escalation "
}
]
},
{
"description": [
{
"lang": "eng",
"value": "Improper Privilege Management."
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-23 Relative Path Traversal"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"url": "https://kb.juniper.net/JSA10975",
"name": "https://kb.juniper.net/JSA10975"
}
]
},
"solution": [
{
"lang": "eng",
"value": "The following software releases have been updated to resolve these specific issues: 15.1F6-S12, 16.1R6-S6, 16.1R7-S3, 17.1R3, 17.2R3-S1, 17.3R3-S3, 17.4R1-S6, 17.4R2-S2, 17.4R3, 18.1R2-S4, 18.1R3-S3, 18.2R2, 18.2R3, 18.2X75-D40, 18.3R1-S2, 18.3R2, 18.4R1-S1, 18.4R2, 19.1R1, and all subsequent releases.\n\n\n"
}
],
"source": {
"advisory": "JSA10975",
"defect": [
"1398333"
],
"discovery": "INTERNAL"
},
"work_around": [
{
"lang": "eng",
"value": "There are no known workarounds for this issue."
}
]
}