"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2024-3640",
|
|
"ASSIGNER": "PSIRT@rockwellautomation.com",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "An unquoted executable path exists in the Rockwell Automation\u00a0FactoryTalk\u00ae Remote Access\u2122 possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-428 Unquoted Search Path or Element",
|
|
"cweId": "CWE-428"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Rockwell Automation",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "FactoryTalk\u00ae Remote Access\u2122",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "v13.5.0.174"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html",
|
|
"refsource": "MISC",
|
|
"name": "https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html"
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.2.0"
|
|
},
|
|
"source": {
|
|
"discovery": "INTERNAL"
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "<ul><li>Corrected in v13.6.</li></ul>"
|
|
}
|
|
],
|
|
"value": "* Corrected in v13.6."
|
|
},
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "\n\n<p>Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices below, where possible. </p><ul><li><p><a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">Security Best Practices</a> </p></li></ul>"
|
|
}
|
|
],
|
|
"value": "Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices below, where possible. \n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
|
|
}
|
|
]
|
|
} |