cvelist/2020/25xxx/CVE-2020-25232.json
2020-12-14 22:02:00 +00:00

62 lines
2.0 KiB
JSON

{
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-25232",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "LOGO! 8 BM (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V8.3"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp."
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480824.pdf",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-480824.pdf"
}
]
}
}