"value": "Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function",
"cweId": "CWE-306"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Billion Electric",
"product": {
"product_data": [
{
"product_name": "M100",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "1.04.1.592.*",
"version_value": "1.04.1.592.8"
},
{
"version_affected": "<",
"version_name": "1.04.1.613.*",
"version_value": "1.04.613.13"
},
{
"version_affected": "<",
"version_name": "1.04.1.*",
"version_value": "1.04.1.675"
}
]
}
},
{
"product_name": "M150",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "1.04.1.592.*",
"version_value": "1.04.1.592.8"
},
{
"version_affected": "<",
"version_name": "1.04.1.613.*",
"version_value": "1.04.613.13"
},
{
"version_affected": "<",
"version_name": "1.04.1.*",
"version_value": "1.04.1.675"
}
]
}
},
{
"product_name": "M120N",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "1.04.1.592.*",
"version_value": "1.04.1.592.8"
},
{
"version_affected": "<",
"version_name": "1.04.1.613.*",
"version_value": "1.04.613.13"
},
{
"version_affected": "<",
"version_name": "1.04.1.*",
"version_value": "1.04.1.675"
}
]
}
},
{
"product_name": "M500",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "1.04.1.592.*",
"version_value": "1.04.1.592.8"
},
{
"version_affected": "<",
"version_name": "1.04.1.613.*",
"version_value": "1.04.613.13"
},
{
"version_affected": "<",
"version_name": "1.04.1.*",
"version_value": "1.04.1.675"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.twcert.org.tw/tw/cp-132-8273-95a07-1.html",
"refsource": "MISC",
"name": "https://www.twcert.org.tw/tw/cp-132-8273-95a07-1.html"
},
{
"url": "https://www.twcert.org.tw/en/cp-139-8274-01e55-2.html",
"refsource": "MISC",
"name": "https://www.twcert.org.tw/en/cp-139-8274-01e55-2.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.2.0"
},
"source": {
"advisory": "TVN-202411025",
"discovery": "EXTERNAL"
},
"solution": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "For firmware version 1.04.1.592.x, please update to 1.04.1.592.8 or later.<br>For firmware version 1.04.1.613.x, please update to 1.04.1.613.13 or later.<br>For all other firmware version 1.04.1.x, please update to 1.04.1.675 or later.<br>"
}
],
"value": "For firmware version 1.04.1.592.x, please update to 1.04.1.592.8 or later.\nFor firmware version 1.04.1.613.x, please update to 1.04.1.613.13 or later.\nFor all other firmware version 1.04.1.x, please update to 1.04.1.675 or later."
}
],
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
]
}
}