"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19297",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens AG",
"product": {
"product_data": [
{
"product_name": "SiNVR 3 Central Control Server (CCS)",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "SiNVR 3 Video Server",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). The streaming service (default port 5410/tcp) of the SiNVR 3 Video Server contains a path traversal vulnerability, that could allow an unauthenticated remote attacker to access and download arbitrary files from the server."
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
}
]
}
}