cvelist/2024/21xxx/CVE-2024-21920.json
2024-04-02 14:16:49 +00:00

107 lines
4.2 KiB
JSON

{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2024-21920",
"ASSIGNER": "PSIRT@rockwellautomation.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "\n\n\nA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\n\n\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read",
"cweId": "CWE-125"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Rockwell Automation",
"product": {
"product_data": [
{
"product_name": "Arena Simulation",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Version 16.00 - 16.20.02"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html",
"refsource": "MISC",
"name": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<ul><li>Do not open untrusted files from unknown sources.</li><li>For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">security best practices</a>&nbsp;to minimize the risk of the vulnerability.</li></ul>\n\n"
}
],
"value": "\n * Do not open untrusted files from unknown sources.\n * For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0to minimize the risk of the vulnerability.\n\n\n\n\n"
}
],
"credits": [
{
"lang": "en",
"value": "Michael Heinzl"
}
],
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L",
"version": "3.1"
}
]
}
}