"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2022-4634",
|
|
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "All versions prior to Delta Electronic\u2019s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-121",
|
|
"cweId": "CWE-121"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Delta Industrial Automation",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "ScreenEditor",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "all versions",
|
|
"version_affected": "="
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CNCSoft",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "all versions",
|
|
"version_affected": "="
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-026-01",
|
|
"refsource": "MISC",
|
|
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-026-01"
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "VINCE 2.0.6",
|
|
"env": "prod",
|
|
"origin": "https://cveawg.mitre.org/api/cve/CVE-2022-4634"
|
|
},
|
|
"source": {
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Delta Electronics released an updated version of CNCSoft and recommends users update to </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1&q=cncsoft&sort_expr=cdate&sort_dir=DESC\">v1.01.34 or later</a><span style=\"background-color: rgb(255, 255, 255);\">. </span>\n\n<br>"
|
|
}
|
|
],
|
|
"value": "\nDelta Electronics released an updated version of CNCSoft and recommends users update to v1.01.34 or later https://downloadcenter.deltaww.com/en-US/DownloadCenter . \n\n\n"
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Simon Humbert, working with Trend Micro Zero Day Initiative"
|
|
}
|
|
],
|
|
"impact": {
|
|
"cvss": [
|
|
{
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "LOCAL",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
]
|
|
}
|
|
} |