mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-05-29 01:31:47 +00:00
110 lines
4.2 KiB
JSON
110 lines
4.2 KiB
JSON
{
|
|
"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2024-2900",
|
|
"ASSIGNER": "cna@vuldb.com",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
|
|
},
|
|
{
|
|
"lang": "deu",
|
|
"value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 gefunden. Dabei betrifft es die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Durch Manipulation des Arguments deviceId/time/urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-121 Stack-based Buffer Overflow",
|
|
"cweId": "CWE-121"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Tenda",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "AC7",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "15.03.06.44"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://vuldb.com/?id.257943",
|
|
"refsource": "MISC",
|
|
"name": "https://vuldb.com/?id.257943"
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?ctiid.257943",
|
|
"refsource": "MISC",
|
|
"name": "https://vuldb.com/?ctiid.257943"
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?submit.300364",
|
|
"refsource": "MISC",
|
|
"name": "https://vuldb.com/?submit.300364"
|
|
},
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md",
|
|
"refsource": "MISC",
|
|
"name": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md"
|
|
}
|
|
]
|
|
},
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "wxhwxhwxh_tutu (VulDB User)"
|
|
}
|
|
],
|
|
"impact": {
|
|
"cvss": [
|
|
{
|
|
"version": "3.1",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
{
|
|
"version": "3.0",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
{
|
|
"version": "2.0",
|
|
"baseScore": 9,
|
|
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"
|
|
}
|
|
]
|
|
}
|
|
} |