"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-10048",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC",
"version": {
"version_data": [
{
"version_value": "All versions < V7.5 SP2"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication."
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf",