"CVE_data_meta": {
|
|
"AKA": "",
|
|
"ASSIGNER": "cve@rapid7.com",
|
|
"DATE_PUBLIC": "2018-06-12T10:00:00.000Z",
|
|
"ID": "CVE-2018-5553",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "Crestron DGE-100 Console Command Injection (FIXED)"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "DGE-100",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"affected": "<=",
|
|
"platform": "",
|
|
"version_name": "",
|
|
"version_value": "1.3384.00049.001"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "TS-1542-C",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"affected": "<=",
|
|
"platform": "",
|
|
"version_name": "",
|
|
"version_value": "1.3384.00049.001"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "DM-DGE-200-C",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"affected": "<=",
|
|
"platform": "",
|
|
"version_name": "",
|
|
"version_value": "1.3384.00049.001"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Crestron"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"configuration": [],
|
|
"credit": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7's vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
|
|
}
|
|
],
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
|
|
}
|
|
]
|
|
},
|
|
"exploit": [],
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"version": "3.0"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": " CWE-78 (Improper Neutralization of Special Elements used in an OS Command)"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553",
|
|
"refsource": "CONFIRM",
|
|
"url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
|
|
},
|
|
{
|
|
"name": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/",
|
|
"refsource": "MISC",
|
|
"url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
|
|
}
|
|
]
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron's product pages."
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "R7-2018-15",
|
|
"defect": [],
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"work_around": []
|
|
} |