cvelist/2023/27xxx/CVE-2023-27917.json
2023-04-11 09:00:34 +00:00

82 lines
4.4 KiB
JSON

{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-27917",
"ASSIGNER": "vultures@jpcert.or.jp",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Contec CO.,LTD.",
"product": {
"product_data": [
{
"product_name": "CONPROSYS IoT Gateway products",
"version": {
"version_data": [
{
"version_value": "M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_cps_230317_en.pdf",
"refsource": "MISC",
"name": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_cps_230317_en.pdf"
},
{
"url": "https://www.contec.com/download/donwload-list/?itemid=f832c526-dcf6-4976-85aa-f536c15a8120#firmware",
"refsource": "MISC",
"name": "https://www.contec.com/download/donwload-list/?itemid=f832c526-dcf6-4976-85aa-f536c15a8120#firmware"
},
{
"url": "https://www.contec.com/download/donwload-list/?itemid=a054b3eb-da97-40d0-9598-d7f5ff4239ec#firmware",
"refsource": "MISC",
"name": "https://www.contec.com/download/donwload-list/?itemid=a054b3eb-da97-40d0-9598-d7f5ff4239ec#firmware"
},
{
"url": "https://www.contec.com/download/donwload-list/?itemid=a1b33f0d-d32b-4549-9741-613cd37d5528#firmware",
"refsource": "MISC",
"name": "https://www.contec.com/download/donwload-list/?itemid=a1b33f0d-d32b-4549-9741-613cd37d5528#firmware"
},
{
"url": "https://jvn.jp/en/vu/JVNVU96198617/",
"refsource": "MISC",
"name": "https://jvn.jp/en/vu/JVNVU96198617/"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "OS command injection vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker who can access Network Maintenance page to execute arbitrary OS commands with a root privilege. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131)."
}
]
}
}