cvelist/2024/39xxx/CVE-2024-39776.json
2024-08-22 20:00:32 +00:00

121 lines
5.5 KiB
JSON

{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2024-39776",
"ASSIGNER": "ics-cert@hq.dhs.gov",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "Avtec Outpost stores sensitive information in an insecure location without proper access controls in place."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-219",
"cweId": "CWE-219"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Avtec",
"product": {
"product_data": [
{
"product_name": "Outpost 0810",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "0",
"version_value": "v5.0.0"
}
]
}
},
{
"product_name": "Outpost Uploader Utility",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "0",
"version_value": "v5.0.0"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-235-04",
"refsource": "MISC",
"name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-235-04"
}
]
},
"generator": {
"engine": "Vulnogram 0.2.0"
},
"source": {
"advisory": "ICSA-24-235-04",
"discovery": "EXTERNAL"
},
"solution": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<p>Avtec recommends users update to Outpost v5.0 to resolve.</p><ul><li>When upgrading to Outpost Version 5.0.0 or later, reset the list of users to the default. More information and instructions can be found on Avtec's <a target=\"_blank\" rel=\"nofollow\" href=\"https://connect.avtecinc.com/bundle/Outpost_Uploader_Utility_User_Guide/page/Content/Outpost_User_Guide/Reset_Web_Auth.html\">Outpost Uploader Utility User Guide</a>&nbsp;for more information.</li><li>Restrict access to port 80 or disable web interface if possible.</li></ul><p>Additionally, Avtec recommends checking devices for Scout firmware versions prior to 5.8.1, which was commonly coupled with Outpost firmware. If so, the devices may also need to be updated to the latest firmware. For more information, please visit <a target=\"_blank\" rel=\"nofollow\" href=\"https://connect.avtecinc.com/bundle/Scout_Release_Notes_5_8/resource/Release_Notes_Scout.pdf\">Scout Release Notes</a>.</p>\n\n<br>"
}
],
"value": "Avtec recommends users update to Outpost v5.0 to resolve.\n\n * When upgrading to Outpost Version 5.0.0 or later, reset the list of users to the default. More information and instructions can be found on Avtec's Outpost Uploader Utility User Guide https://connect.avtecinc.com/bundle/Outpost_Uploader_Utility_User_Guide/page/Content/Outpost_User_Guide/Reset_Web_Auth.html \u00a0for more information.\n * Restrict access to port 80 or disable web interface if possible.\n\n\nAdditionally, Avtec recommends checking devices for Scout firmware versions prior to 5.8.1, which was commonly coupled with Outpost firmware. If so, the devices may also need to be updated to the latest firmware. For more information, please visit Scout Release Notes https://connect.avtecinc.com/bundle/Scout_Release_Notes_5_8/resource/Release_Notes_Scout.pdf ."
}
],
"credits": [
{
"lang": "en",
"value": "Jonathan Fournier of Field Effect reported these vulnerabilities to CISA."
}
],
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
]
}
}