"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2024-3904",
|
|
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions \"05\" to \"07\" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-276 Incorrect Default Permissions",
|
|
"cweId": "CWE-276"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Mitsubishi Electric Corporation",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "MELIPC Series MI5122-VW",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "Firmware versions \"05\" to \"07\""
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf",
|
|
"refsource": "MISC",
|
|
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf"
|
|
},
|
|
{
|
|
"url": "https://jvn.jp/vu/JVNVU91215350/index.html",
|
|
"refsource": "MISC",
|
|
"name": "https://jvn.jp/vu/JVNVU91215350/index.html"
|
|
},
|
|
{
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-02",
|
|
"refsource": "MISC",
|
|
"name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-02"
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.2.0"
|
|
},
|
|
"source": {
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"impact": {
|
|
"cvss": [
|
|
{
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "LOCAL",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
]
|
|
}
|
|
} |