"id": "CVE-2022-23448",
"sourceIdentifier": "productcert@siemens.com",
"published": "2022-04-12T09:15:14.233",
"lastModified": "2024-11-21T06:48:34.530",
"vulnStatus": "Modified",
"cveTags": [],
2023-04-24 12:24:31 +02:00
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones anteriores a V7.3 Update 1), SIMATIC Energy Manager PRO (todas las versiones anteriores a V7.3 Update 1). Las aplicaciones afectadas asignan inapropiadamente los permisos a directorios y archivos cr\u00edticos usados por los procesos de la aplicaci\u00f3n. Esto podr\u00eda permitir a un atacante local no privilegiado lograr la ejecuci\u00f3n de c\u00f3digo con privilegios de ADMINISTRADOR o incluso de NT AUTHORITY/SYSTEM"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
2023-04-24 12:24:31 +02:00
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
2023-04-24 12:24:31 +02:00
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"baseScore": 7.2,
2023-04-24 12:24:31 +02:00
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
2023-04-24 12:24:31 +02:00
},
"baseSeverity": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
2023-04-24 12:24:31 +02:00
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
2023-04-24 12:24:31 +02:00
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*",
"versionEndExcluding": "7.3",
"matchCriteriaId": "2BDBCB2C-E9EB-4AF6-B47A-22B27AE41178"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*",
"matchCriteriaId": "1BB78E93-7C0A-4F59-B6EA-3D5A681BFE8F"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*",
"versionEndExcluding": "7.3",
"matchCriteriaId": "4B1E608C-3C6F-45FB-86C9-E99E7F21836D"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*",
"matchCriteriaId": "34A11AF9-7F0C-4151-8A4D-A8E1BDCBA525"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}