2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-24661" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2022-03-08T12:15:11.677" ,
2024-11-23 15:12:23 +00:00
"lastModified" : "2024-11-21T06:50:48.887" ,
"vulnStatus" : "Modified" ,
2024-12-08 03:06:42 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2022.1). The starview+.exe contains a memory corruption vulnerability while parsing specially crafted .SCE files. This could allow an attacker to execute code in the context of the current process."
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en Simcenter STAR-CCM+ Viewer (Todas las versiones anteriores a la versi\u00f3n V2022.1). El starview+.exe contiene una vulnerabilidad de corrupci\u00f3n de memoria al analizar archivos .SCE especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual"
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" ,
2024-11-23 15:12:23 +00:00
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "REQUIRED" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-11-23 15:12:23 +00:00
"availabilityImpact" : "HIGH"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:N/AC:M/Au:N/C:P/I:P/A:P" ,
2024-11-23 15:12:23 +00:00
"baseScore" : 6.8 ,
2023-04-24 12:24:31 +02:00
"accessVector" : "NETWORK" ,
"accessComplexity" : "MEDIUM" ,
"authentication" : "NONE" ,
"confidentialityImpact" : "PARTIAL" ,
"integrityImpact" : "PARTIAL" ,
2024-11-23 15:12:23 +00:00
"availabilityImpact" : "PARTIAL"
2023-04-24 12:24:31 +02:00
} ,
"baseSeverity" : "MEDIUM" ,
"exploitabilityScore" : 8.6 ,
"impactScore" : 6.4 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : true
}
]
} ,
"weaknesses" : [
{
2024-11-23 15:12:23 +00:00
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
2023-04-24 12:24:31 +02:00
"description" : [
{
"lang" : "en" ,
2024-11-23 15:12:23 +00:00
"value" : "CWE-119"
2023-04-24 12:24:31 +02:00
}
]
} ,
{
2024-11-23 15:12:23 +00:00
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"description" : [
{
"lang" : "en" ,
2024-11-23 15:12:23 +00:00
"value" : "CWE-787"
2023-04-24 12:24:31 +02:00
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:simcenter_star-ccm\\+_viewer:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "2022.1" ,
"matchCriteriaId" : "B1C459A8-8F6A-4DA0-BD39-BE0FF57F95BE"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-166747.pdf" ,
"source" : "productcert@siemens.com" ,
"tags" : [
"Mitigation" ,
"Patch" ,
"Vendor Advisory"
]
2024-11-23 15:12:23 +00:00
} ,
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-166747.pdf" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Mitigation" ,
"Patch" ,
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}