2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2023-29410" ,
"sourceIdentifier" : "cybersecurity@se.com" ,
"published" : "2023-04-18T22:15:08.067" ,
2023-04-28 04:00:28 +02:00
"lastModified" : "2023-04-28T01:25:19.217" ,
"vulnStatus" : "Analyzed" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "\nA CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated\nattacker to gain the same privilege as the application on the server when a malicious payload is\nprovided over HTTP for the server to execute. \n\n \n\n\n\n"
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-04-28 04:00:28 +02:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 8.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.9
} ,
2023-04-24 12:24:31 +02:00
{
"source" : "cybersecurity@se.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "HIGH" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.2 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.2 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "cybersecurity@se.com" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-20"
}
]
}
] ,
2023-04-28 04:00:28 +02:00
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:insighthome_firmware:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "1.16" ,
"matchCriteriaId" : "371B602D-2BB3-41CF-B07B-558B74AEC130"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:insighthome_firmware:1.16:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "698CF5CB-17DC-405B-9C44-675A80320A65"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:insighthome_firmware:1.16:build_004:*:*:*:*:*:*" ,
"matchCriteriaId" : "039691CA-D243-4D6D-912A-F130F7F6491C"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:insighthome:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "37CAC057-7F0E-4375-99FE-AEE0EDDEA568"
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:insightfacility_firmware:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "1.16" ,
"matchCriteriaId" : "18E2843D-745F-41D7-8B16-2CC18EC64290"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:insightfacility_firmware:1.16:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "F90B0024-6C86-4E85-AE83-F349D34E7416"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:insightfacility_firmware:1.16:build_004:*:*:*:*:*:*" ,
"matchCriteriaId" : "D81ACD8E-4B04-4BCB-894F-4A5828899C16"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:insightfacility:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "F5011815-3D43-4AA4-9395-31788D06DA10"
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:conext_gateway_firmware:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "1.16" ,
"matchCriteriaId" : "3524289C-ACF3-424E-9A1E-A777EBFB89F1"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:conext_gateway_firmware:1.16:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "62314597-62BC-4531-B5C8-61343262CE9E"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:conext_gateway_firmware:1.16:build_004:*:*:*:*:*:*" ,
"matchCriteriaId" : "AD27299F-4422-4176-9DFD-86F2E4487366"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:conext_gateway:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "E013171F-2BFB-4CB2-9C4B-4EB60A40B255"
}
]
}
]
}
] ,
2023-04-24 12:24:31 +02:00
"references" : [
{
"url" : "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-02.pdf" ,
2023-04-28 04:00:28 +02:00
"source" : "cybersecurity@se.com" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}