2023-10-04 20:00:30 +00:00
{
"id" : "CVE-2023-5402" ,
"sourceIdentifier" : "cybersecurity@se.com" ,
"published" : "2023-10-04T18:15:12.240" ,
2023-10-11 20:00:28 +00:00
"lastModified" : "2023-10-11T19:19:54.037" ,
"vulnStatus" : "Analyzed" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-10-04 20:00:30 +00:00
"descriptions" : [
{
"lang" : "en" ,
2023-10-11 10:00:29 +00:00
"value" : "\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n"
} ,
{
"lang" : "es" ,
2023-10-11 20:00:28 +00:00
"value" : "CWE-269: Existe una vulnerabilidad de gesti\u00f3n de privilegios inadecuada, que podr\u00eda provocar una ejecuci\u00f3n remota de c\u00f3digo cuando se utiliza el comando de transferencia a trav\u00e9s de la red."
2023-10-04 20:00:30 +00:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-10-11 20:00:28 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 9.8 ,
"baseSeverity" : "CRITICAL"
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 5.9
} ,
2023-10-04 20:00:30 +00:00
{
"source" : "cybersecurity@se.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 9.8 ,
"baseSeverity" : "CRITICAL"
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "cybersecurity@se.com" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-269"
}
]
}
] ,
2023-10-11 20:00:28 +00:00
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*" ,
"versionEndIncluding" : "1.16.3" ,
"matchCriteriaId" : "93758686-7EEE-462D-80FE-D5AFA520DD8A"
}
]
}
]
}
] ,
2023-10-04 20:00:30 +00:00
"references" : [
{
"url" : "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-01.pdf" ,
2023-10-11 20:00:28 +00:00
"source" : "cybersecurity@se.com" ,
"tags" : [
"Vendor Advisory"
]
2023-10-04 20:00:30 +00:00
}
]
}