"id": "CVE-2024-27907",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-03-12T11:15:49.720",
"lastModified": "2024-03-12T12:40:13.500",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions < V2306.0000). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22051)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Simcenter Femap (Todas las versiones &lt; V2306.0000). La aplicaci\u00f3n afectada contiene una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado mientras analiza un archivo Catia MODEL especialmente manipulado. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-22051)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-000072.html",
"source": "productcert@siemens.com"
}
]
}