117 lines
3.7 KiB
JSON
Raw Normal View History

2023-04-24 12:24:31 +02:00
{
"id": "CVE-2018-13014",
"sourceIdentifier": "cve@mitre.org",
"published": "2018-06-29T15:29:00.367",
"lastModified": "2019-10-03T00:03:26.223",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Storing password in recoverable format in safensec.com (SysWatch service) in SAFE'N'SEC SoftControl/SafenSoft SysWatch, SoftControl/SafenSoft TPSecure, and SoftControl/SafenSoft Enterprise Suite before 4.4.2 allows the local attacker to restore the SysWatch password from the settings database and modify program settings."
},
{
"lang": "es",
"value": "Almacenar la contrase\u00f1a en formato recuperable en safensec.com (servicio SysWatch) en SAFE'N'SEC SoftControl/SafenSoft SysWatch, SoftControl/SafenSoft TPSecure y SoftControl/SafenSoft Enterprise Suite en versiones anteriores a la 4.4.2 permite al atacante local restaurar la contrase\u00f1a SysWatch desde la base de datos de configuraci\u00f3n y modificar la configuraci\u00f3n del programa."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1
},
"baseSeverity": "LOW",
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:safensoft:enterprise_suite:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.4.2",
"matchCriteriaId": "ADE48A52-8384-4F2E-9E12-0D4D1D54FCFD"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:safensoft:syswatch:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.4.2",
"matchCriteriaId": "5B6ADD1F-DDE6-45E5-BA0D-74661AA00F17"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:safensoft:tpsecure:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.4.2",
"matchCriteriaId": "B0CD8170-4CC4-4F46-88C4-0C4731103581"
}
]
}
]
}
],
"references": [
{
"url": "http://www.safensoft.com/security.phtml?c=865#SNSVE-2018-2",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}