mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-29 01:31:20 +00:00
105 lines
2.9 KiB
JSON
105 lines
2.9 KiB
JSON
![]() |
{
|
||
|
"id": "CVE-2018-7118",
|
||
|
"sourceIdentifier": "security-alert@hpe.com",
|
||
|
"published": "2019-04-09T19:29:01.677",
|
||
|
"lastModified": "2020-08-24T17:37:01.140",
|
||
|
"vulnStatus": "Analyzed",
|
||
|
"descriptions": [
|
||
|
{
|
||
|
"lang": "en",
|
||
|
"value": "A local access restriction bypass vulnerability was identified in HPE Service Pack for ProLiant (SPP) Bundled Software earlier than version 2018.09.0."
|
||
|
},
|
||
|
{
|
||
|
"lang": "es",
|
||
|
"value": "Una vulnerabilidad de omisi\u00f3n de restricci\u00f3n de acceso local, fue identificada en HPE Service Pack para el software ProLiant (SPP) Bundled en las versiones anteriores a 2018.09.0."
|
||
|
}
|
||
|
],
|
||
|
"metrics": {
|
||
|
"cvssMetricV30": [
|
||
|
{
|
||
|
"source": "nvd@nist.gov",
|
||
|
"type": "Primary",
|
||
|
"cvssData": {
|
||
|
"version": "3.0",
|
||
|
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
||
|
"attackVector": "LOCAL",
|
||
|
"attackComplexity": "LOW",
|
||
|
"privilegesRequired": "LOW",
|
||
|
"userInteraction": "NONE",
|
||
|
"scope": "UNCHANGED",
|
||
|
"confidentialityImpact": "HIGH",
|
||
|
"integrityImpact": "HIGH",
|
||
|
"availabilityImpact": "HIGH",
|
||
|
"baseScore": 7.8,
|
||
|
"baseSeverity": "HIGH"
|
||
|
},
|
||
|
"exploitabilityScore": 1.8,
|
||
|
"impactScore": 5.9
|
||
|
}
|
||
|
],
|
||
|
"cvssMetricV2": [
|
||
|
{
|
||
|
"source": "nvd@nist.gov",
|
||
|
"type": "Primary",
|
||
|
"cvssData": {
|
||
|
"version": "2.0",
|
||
|
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
|
||
|
"accessVector": "LOCAL",
|
||
|
"accessComplexity": "LOW",
|
||
|
"authentication": "NONE",
|
||
|
"confidentialityImpact": "PARTIAL",
|
||
|
"integrityImpact": "PARTIAL",
|
||
|
"availabilityImpact": "PARTIAL",
|
||
|
"baseScore": 4.6
|
||
|
},
|
||
|
"baseSeverity": "MEDIUM",
|
||
|
"exploitabilityScore": 3.9,
|
||
|
"impactScore": 6.4,
|
||
|
"acInsufInfo": false,
|
||
|
"obtainAllPrivilege": false,
|
||
|
"obtainUserPrivilege": false,
|
||
|
"obtainOtherPrivilege": false,
|
||
|
"userInteractionRequired": false
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
"weaknesses": [
|
||
|
{
|
||
|
"source": "nvd@nist.gov",
|
||
|
"type": "Primary",
|
||
|
"description": [
|
||
|
{
|
||
|
"lang": "en",
|
||
|
"value": "NVD-CWE-noinfo"
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
],
|
||
|
"configurations": [
|
||
|
{
|
||
|
"nodes": [
|
||
|
{
|
||
|
"operator": "OR",
|
||
|
"negate": false,
|
||
|
"cpeMatch": [
|
||
|
{
|
||
|
"vulnerable": true,
|
||
|
"criteria": "cpe:2.3:a:hp:service_pack_for_proliant:*:*:*:*:*:*:*:*",
|
||
|
"versionEndExcluding": "2018.09.0",
|
||
|
"matchCriteriaId": "C8F172EB-EE17-42DC-8D4C-6303B206627C"
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
],
|
||
|
"references": [
|
||
|
{
|
||
|
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03904en_us",
|
||
|
"source": "security-alert@hpe.com",
|
||
|
"tags": [
|
||
|
"Vendor Advisory"
|
||
|
]
|
||
|
}
|
||
|
]
|
||
|
}
|