"value": "An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords."
},
{
"lang": "es",
"value": "Ha sido descubierto un problema en BINOM3 Universal Multifunctional Electric Power Quality Meter. Los usuarios no tienen ninguna opci\u00f3n para cambiar sus propias contrase\u00f1as."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"availabilityImpact": "LOW",
"baseScore": 8.6,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 4.7
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:binom3:universal_multifunctional_electric_power_quality_meter_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AD3D22CB-94D8-4066-8D92-6B3EE21A1C19"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:binom3:universal_multifunctional_electric_power_quality_meter:-:*:*:*:*:*:*:*",
"matchCriteriaId": "43E83CFB-E822-4C19-A8FE-9A4F88A9E545"
}
]
}
]
}
],
"references": [
{
"url": "http://www.securityfocus.com/bid/93028",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-031-01A",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
}
]
}