111 lines
3.3 KiB
JSON
Raw Normal View History

2023-04-24 12:24:31 +02:00
{
"id": "CVE-2022-38744",
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"published": "2022-10-27T14:15:10.777",
"lastModified": "2023-11-07T03:50:14.327",
"vulnStatus": "Modified",
"cveTags": [],
2023-04-24 12:24:31 +02:00
"descriptions": [
{
"lang": "en",
"value": "\nAn unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and \nEvents service could open a connection, causing the service to fault and become unavailable. The affected port \ncould be used as a server ping port and uses messages structured with XML.\n\n\n"
},
{
"lang": "es",
"value": "Un atacante no autenticado con acceso a la red de la v\u00edctima del servicio de Eventos y Alarmas FactoryTalk de Rockwell Automation podr\u00eda abrir una conexi\u00f3n, provocando que el servicio falle y deje de estar disponible. El puerto afectado podr\u00eda utilizarse como puerto de ping del servidor y utiliza mensajes estructurados con XML."
2023-04-24 12:24:31 +02:00
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
},
{
"source": "PSIRT@rockwellautomation.com",
2023-04-24 12:24:31 +02:00
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"source": "PSIRT@rockwellautomation.com",
2023-04-24 12:24:31 +02:00
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_alarms_and_events:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CCB45744-EA5E-47AF-B3F2-5E73FE108897"
}
]
}
]
}
],
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1136876",
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Permissions Required",
"Vendor Advisory"
]
}
]
}