"id" : "CVE-2022-46141" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2023-12-12T12:15:10.003" ,
2024-12-08 03:06:42 +00:00
"lastModified" : "2024-11-21T07:30:10.817" ,
"vulnStatus" : "Modified" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-12-12 15:05:13 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application."
2023-12-15 17:00:28 +00:00
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) (todas las versiones < V19). Una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n podr\u00eda permitir a un atacante local obtener acceso a la contrase\u00f1a de nivel de acceso de las CPU SIMATIC S7-1200 y S7-1500, cuando la ingresa un usuario leg\u00edtimo en la configuraci\u00f3n de hardware de la aplicaci\u00f3n afectada."
2023-12-12 15:05:13 +00:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
2024-12-08 03:06:42 +00:00
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
2023-12-15 17:00:28 +00:00
"cvssData" : {
"version" : "3.1" ,
2024-12-08 03:06:42 +00:00
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N" ,
"baseScore" : 4.2 ,
"baseSeverity" : "MEDIUM" ,
2023-12-15 17:00:28 +00:00
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
2024-12-08 03:06:42 +00:00
"privilegesRequired" : "HIGH" ,
"userInteraction" : "REQUIRED" ,
2023-12-15 17:00:28 +00:00
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "NONE" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "NONE"
2023-12-15 17:00:28 +00:00
} ,
2024-12-08 03:06:42 +00:00
"exploitabilityScore" : 0.6 ,
2023-12-15 17:00:28 +00:00
"impactScore" : 3.6
} ,
{
2024-12-08 03:06:42 +00:00
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
2023-12-12 15:05:13 +00:00
"cvssData" : {
"version" : "3.1" ,
2024-12-08 03:06:42 +00:00
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" ,
"baseScore" : 5.5 ,
"baseSeverity" : "MEDIUM" ,
2023-12-12 15:05:13 +00:00
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
2024-12-08 03:06:42 +00:00
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
2023-12-12 15:05:13 +00:00
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "NONE" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "NONE"
2023-12-12 15:05:13 +00:00
} ,
2024-12-08 03:06:42 +00:00
"exploitabilityScore" : 1.8 ,
2023-12-12 15:05:13 +00:00
"impactScore" : 3.6
}
]
} ,
"weaknesses" : [
{
2024-12-08 03:06:42 +00:00
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
2023-12-15 17:00:28 +00:00
"description" : [
{
"lang" : "en" ,
2024-12-08 03:06:42 +00:00
"value" : "CWE-316"
2023-12-15 17:00:28 +00:00
}
]
} ,
{
2024-12-08 03:06:42 +00:00
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
2023-12-12 15:05:13 +00:00
"description" : [
{
"lang" : "en" ,
2024-12-08 03:06:42 +00:00
"value" : "CWE-312"
2023-12-12 15:05:13 +00:00
}
]
}
] ,
2023-12-15 17:00:28 +00:00
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "19" ,
"matchCriteriaId" : "F77226E4-F3B3-4D3B-B944-17CED48BD73A"
}
]
}
]
}
] ,
2023-12-12 15:05:13 +00:00
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf" ,
2023-12-15 17:00:28 +00:00
"source" : "productcert@siemens.com" ,
"tags" : [
"Vendor Advisory"
]
2024-12-08 03:06:42 +00:00
} ,
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Vendor Advisory"
]
2023-12-12 15:05:13 +00:00
}
]
}