2024-08-15 18:03:30 +00:00
{
"id" : "CVE-2024-31799" ,
"sourceIdentifier" : "cve@mitre.org" ,
"published" : "2024-08-15T17:15:17.127" ,
2024-08-16 20:03:12 +00:00
"lastModified" : "2024-08-16T18:35:10.927" ,
"vulnStatus" : "Modified" ,
2024-08-15 18:03:30 +00:00
"cveTags" : [ ] ,
"descriptions" : [
{
"lang" : "en" ,
"value" : "Information Disclosure in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to read the WiFi passphrase via the UART Debugging Port."
2024-08-16 14:03:13 +00:00
} ,
{
"lang" : "es" ,
"value" : " La divulgaci\u00f3n de informaci\u00f3n en GNCC's GC2 Indoor Security Camera 1080P permite a un atacante con acceso f\u00edsico leer la frase de contrase\u00f1a de WiFi a trav\u00e9s del puerto de depuraci\u00f3n UART."
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" ,
"attackVector" : "PHYSICAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 4.6 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 0.9 ,
"impactScore" : 3.6
2024-08-16 20:03:12 +00:00
} ,
{
"source" : "134c704f-9b21-4f2e-91b3-4a467353bcc0" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" ,
"attackVector" : "PHYSICAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 4.6 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 0.9 ,
"impactScore" : 3.6
2024-08-16 14:03:13 +00:00
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-319"
}
]
2024-08-16 20:03:12 +00:00
} ,
{
"source" : "134c704f-9b21-4f2e-91b3-4a467353bcc0" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-200"
}
]
2024-08-16 14:03:13 +00:00
}
] ,
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:gncchome:gncc_c2_firmware:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "FD479C7A-72DD-4266-B7D6-730ED8D9F3C7"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:gncchome:_gncc_c2:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "A8F1C15B-9990-41D5-96DE-E3E8FD1D7A68"
}
]
}
]
2024-08-15 18:03:30 +00:00
}
] ,
"references" : [
{
"url" : "https://gncchome.com/collections/indoor-camera/products/c2-indoor-security-camera-1080p" ,
2024-08-16 14:03:13 +00:00
"source" : "cve@mitre.org" ,
"tags" : [
"Product"
]
2024-08-15 18:03:30 +00:00
} ,
{
"url" : "https://www.nsideattacklogic.de/advisories/NSIDE-SA-2024-001" ,
2024-08-16 14:03:13 +00:00
"source" : "cve@mitre.org" ,
"tags" : [
"Exploit" ,
"Third Party Advisory"
]
2024-08-15 18:03:30 +00:00
}
]
}