"id" : "CVE-2024-49775" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2024-12-16T15:15:07.173" ,
"lastModified" : "2024-12-16T15:15:07.173" ,
2024-12-22 03:03:49 +00:00
"vulnStatus" : "Awaiting Analysis" ,
2024-12-16 17:04:17 +00:00
"cveTags" : [ ] ,
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in Opcenter Execution Foundation (All versions), Opcenter Intelligence (All versions), Opcenter Quality (All versions), Opcenter RDL (All versions), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.\r\nThis could allow an unauthenticated remote attacker to execute arbitrary code."
2024-12-22 03:03:49 +00:00
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en Opcenter Execution Foundation (todas las versiones), Opcenter Intelligence (todas las versiones), Opcenter Quality (todas las versiones), Opcenter RDL (todas las versiones), SIMATIC PCS neo V4.0 (todas las versiones), SIMATIC PCS neo V4.1 (todas las versiones), SIMATIC PCS neo V5.0 (todas las versiones < V5.0 Update 1), SINEC NMS (todas las versiones si se utilizan junto con UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V18 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V19 (todas las versiones). Los productos afectados contienen una vulnerabilidad de desbordamiento de b\u00fafer basada en mont\u00f3n en el componente UMC integrado. Esto podr\u00eda permitir que un atacante remoto no autenticado ejecute c\u00f3digo arbitrario."
2024-12-16 17:04:17 +00:00
}
] ,
"metrics" : {
"cvssMetricV40" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "4.0" ,
"vectorString" : "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X" ,
"baseScore" : 9.3 ,
"baseSeverity" : "CRITICAL" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"attackRequirements" : "NONE" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
2025-03-02 03:03:52 +00:00
"vulnConfidentialityImpact" : "HIGH" ,
"vulnIntegrityImpact" : "HIGH" ,
"vulnAvailabilityImpact" : "HIGH" ,
"subConfidentialityImpact" : "NONE" ,
"subIntegrityImpact" : "NONE" ,
"subAvailabilityImpact" : "NONE" ,
2024-12-16 17:04:17 +00:00
"exploitMaturity" : "NOT_DEFINED" ,
2025-03-02 03:03:52 +00:00
"confidentialityRequirement" : "NOT_DEFINED" ,
"integrityRequirement" : "NOT_DEFINED" ,
"availabilityRequirement" : "NOT_DEFINED" ,
2024-12-16 17:04:17 +00:00
"modifiedAttackVector" : "NOT_DEFINED" ,
"modifiedAttackComplexity" : "NOT_DEFINED" ,
"modifiedAttackRequirements" : "NOT_DEFINED" ,
"modifiedPrivilegesRequired" : "NOT_DEFINED" ,
"modifiedUserInteraction" : "NOT_DEFINED" ,
2025-03-02 03:03:52 +00:00
"modifiedVulnConfidentialityImpact" : "NOT_DEFINED" ,
"modifiedVulnIntegrityImpact" : "NOT_DEFINED" ,
"modifiedVulnAvailabilityImpact" : "NOT_DEFINED" ,
"modifiedSubConfidentialityImpact" : "NOT_DEFINED" ,
"modifiedSubIntegrityImpact" : "NOT_DEFINED" ,
"modifiedSubAvailabilityImpact" : "NOT_DEFINED" ,
"Safety" : "NOT_DEFINED" ,
"Automatable" : "NOT_DEFINED" ,
"Recovery" : "NOT_DEFINED" ,
2024-12-16 17:04:17 +00:00
"valueDensity" : "NOT_DEFINED" ,
"vulnerabilityResponseEffort" : "NOT_DEFINED" ,
"providerUrgency" : "NOT_DEFINED"
}
}
] ,
"cvssMetricV31" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 9.8 ,
"baseSeverity" : "CRITICAL" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH"
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-122"
}
]
}
] ,
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/html/ssa-928984.html" ,
"source" : "productcert@siemens.com"
}
]
}