2023-10-10 12:00:30 +00:00
{
"id" : "CVE-2022-30527" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2023-10-10T11:15:10.603" ,
2024-12-08 03:06:42 +00:00
"lastModified" : "2024-11-21T07:02:52.990" ,
2024-07-09 14:03:16 +00:00
"vulnStatus" : "Modified" ,
"cveTags" : [ ] ,
2023-10-10 12:00:30 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application assigns improper access rights to specific folders containing executable files and libraries.\r\n\r\nThis could allow an authenticated local attacker to inject arbitrary code and escalate privileges."
2023-10-10 14:00:28 +00:00
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones < V2.0). La aplicaci\u00f3n afectada asigna derechos de acceso indebidos a carpetas espec\u00edficas que contienen librer\u00edas y archivos ejecutables. Esto podr\u00eda permitir que un atacante local autenticado inyecte c\u00f3digo arbitrario y escale privilegios."
2023-10-10 12:00:30 +00:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
2024-12-08 03:06:42 +00:00
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH" ,
2023-10-10 12:00:30 +00:00
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "HIGH"
2023-10-10 12:00:30 +00:00
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "productcert@siemens.com" ,
2024-12-15 03:03:56 +00:00
"type" : "Primary" ,
2023-10-10 12:00:30 +00:00
"description" : [
{
"lang" : "en" ,
"value" : "CWE-732"
}
]
}
] ,
2023-10-16 20:00:28 +00:00
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "2.0" ,
"matchCriteriaId" : "A7F0A543-38E1-48B9-A984-259081E49EAA"
}
]
}
]
}
] ,
2023-10-10 12:00:30 +00:00
"references" : [
2024-07-09 14:03:16 +00:00
{
"url" : "https://cert-portal.siemens.com/productcert/html/ssa-160243.html" ,
"source" : "productcert@siemens.com"
} ,
2023-10-10 12:00:30 +00:00
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf" ,
2023-10-16 20:00:28 +00:00
"source" : "productcert@siemens.com" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2024-12-08 03:06:42 +00:00
} ,
{
"url" : "https://cert-portal.siemens.com/productcert/html/ssa-160243.html" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108"
} ,
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2023-10-10 12:00:30 +00:00
}
]
}