2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2023-25556" ,
"sourceIdentifier" : "cybersecurity@se.com" ,
"published" : "2023-04-18T18:15:07.357" ,
2024-12-08 03:06:42 +00:00
"lastModified" : "2024-11-21T07:49:43.417" ,
"vulnStatus" : "Modified" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "\nA CWE-287: Improper Authentication vulnerability exists that could allow a device to be\ncompromised when a key of less than seven digits is entered and the attacker has access to the\nKNX installation.\n\n"
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-04-28 16:00:32 +02:00
{
2024-12-08 03:06:42 +00:00
"source" : "cybersecurity@se.com" ,
"type" : "Secondary" ,
2023-04-28 16:00:32 +02:00
"cvssData" : {
"version" : "3.1" ,
2024-12-08 03:06:42 +00:00
"vectorString" : "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H" ,
"baseScore" : 8.3 ,
"baseSeverity" : "HIGH" ,
2023-04-28 16:00:32 +02:00
"attackVector" : "ADJACENT_NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
2024-12-08 03:06:42 +00:00
"confidentialityImpact" : "LOW" ,
2023-04-28 16:00:32 +02:00
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "HIGH"
2023-04-28 16:00:32 +02:00
} ,
"exploitabilityScore" : 2.8 ,
2024-12-08 03:06:42 +00:00
"impactScore" : 5.5
2023-04-28 16:00:32 +02:00
} ,
2023-04-24 12:24:31 +02:00
{
2024-12-08 03:06:42 +00:00
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"cvssData" : {
"version" : "3.1" ,
2024-12-08 03:06:42 +00:00
"vectorString" : "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 8.8 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "ADJACENT_NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
2024-12-08 03:06:42 +00:00
"confidentialityImpact" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "HIGH"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 2.8 ,
2024-12-08 03:06:42 +00:00
"impactScore" : 5.9
2023-04-24 12:24:31 +02:00
}
]
} ,
"weaknesses" : [
{
"source" : "cybersecurity@se.com" ,
2024-12-15 03:03:56 +00:00
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"description" : [
{
"lang" : "en" ,
"value" : "CWE-287"
}
]
}
] ,
2023-04-28 16:00:32 +02:00
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_instabus_tastermodul_1fach_system_m_firmware:1.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "07A53874-254C-4CA0-9CA8-387094723B4A"
2023-04-28 16:00:32 +02:00
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:merten_instabus_tastermodul_1fach_system_m:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "29918B0B-9089-46B0-B86E-B78BFB5F0DB6"
2023-04-28 16:00:32 +02:00
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_instabus_tastermodul_2fach_system_m_firmware:1.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "10E0A138-4F3A-434D-B52D-5EE91CD7E2EA"
2023-04-28 16:00:32 +02:00
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:merten_instabus_tastermodul_2fach_system_m:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "D4676AD5-F82E-42C0-B6A2-3D57F075C532"
2023-04-28 16:00:32 +02:00
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-05-19 02:03:31 +00:00
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_tasterschnittstelle_4fach_plus_firmware:1.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "F7B565DF-3403-45E2-8C12-010DAFDA308E"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_tasterschnittstelle_4fach_plus_firmware:1.2:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "5CA73BB4-92DA-49BF-89D6-B037EF16F963"
2023-04-28 16:00:32 +02:00
}
]
2024-12-08 03:06:42 +00:00
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:merten_tasterschnittstelle_4fach_plus:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "46DEB9E7-1212-4BCA-8C23-72B2F45A97BF"
}
]
2023-04-28 16:00:32 +02:00
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_knx_argus_180\\/2\\,20m_up_system_firmware:1.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "F9D64205-D9F0-4199-8BEF-68979E7DB147"
2023-04-28 16:00:32 +02:00
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:merten_knx_argus_180\\/2\\,20m_up_system:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "559DECE9-5779-40B5-AF91-C97B3731AF73"
2023-04-28 16:00:32 +02:00
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_jalousie-\\/schaltaktor_reg-k\\/8x\\/16x\\/10_m._hb_firmware:1.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "65F4A4D6-B1EF-41DC-B392-8BE542F473A2"
2023-04-28 16:00:32 +02:00
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:merten_jalousie-\\/schaltaktor_reg-k\\/8x\\/16x\\/10_m._hb:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "0FAF80D9-ED66-4D7A-8E1F-80D096B95DC6"
2023-04-28 16:00:32 +02:00
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-05-19 02:03:31 +00:00
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_knx_uni-dimmaktor_ll_reg-k\\/2x230\\/300_w_firmware:1.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "F7709BD4-99D8-4155-8EDE-62D4E58096FD"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_knx_uni-dimmaktor_ll_reg-k\\/2x230\\/300_w_firmware:1.1:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "A79222B6-2823-40D8-9A4B-52140789C7F6"
2023-04-28 16:00:32 +02:00
}
]
2024-12-08 03:06:42 +00:00
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:merten_knx_uni-dimmaktor_ll_reg-k\\/2x230\\/300_w:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "DC7716A5-1CF8-4B90-952F-64E1B160BB2C"
}
]
2023-04-28 16:00:32 +02:00
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:schneider-electric:merten_knx_schaltakt.2x6a_up_m.2_eing._firmware:0.1:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "501E6F54-418C-46A1-997B-CE3AAEBF0D2F"
2023-04-28 16:00:32 +02:00
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
2024-12-08 03:06:42 +00:00
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:schneider-electric:merten_knx_schaltakt.2x6a_up_m.2_eing.:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "0B2F19DC-9F7A-431D-B0F9-559A9D49F53B"
2023-04-28 16:00:32 +02:00
}
]
}
]
}
] ,
2023-04-24 12:24:31 +02:00
"references" : [
{
"url" : "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-03.pdf" ,
2023-04-28 16:00:32 +02:00
"source" : "cybersecurity@se.com" ,
"tags" : [
"Vendor Advisory"
]
2024-12-08 03:06:42 +00:00
} ,
{
"url" : "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-03.pdf" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}