72 lines
3.0 KiB
JSON
Raw Normal View History

{
"id": "CVE-2023-39466",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"published": "2024-05-03T03:15:12.193",
"lastModified": "2024-11-21T08:15:28.803",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway get_config Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n de autenticaci\u00f3n faltante. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. No se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe dentro del endpoint get_config. El problema se debe a la falta de autenticaci\u00f3n antes de permitir el acceso a la funcionalidad. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n confidencial. Era ZDI-CAN-20797."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
]
},
"weaknesses": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"references": [
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1034/",
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1034/",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
]
}