2023-06-13 10:00:30 +00:00
{
"id" : "CVE-2023-28829" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2023-06-13T09:15:16.707" ,
2023-07-05 18:00:37 +00:00
"lastModified" : "2023-07-05T17:36:45.750" ,
"vulnStatus" : "Analyzed" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-06-13 10:00:30 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents."
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-07-05 18:00:37 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 8.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.9
} ,
2023-06-13 10:00:30 +00:00
{
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L" ,
"attackVector" : "ADJACENT_NETWORK" ,
"attackComplexity" : "HIGH" ,
"privilegesRequired" : "HIGH" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "LOW" ,
"integrityImpact" : "LOW" ,
"availabilityImpact" : "LOW" ,
"baseScore" : 3.9 ,
"baseSeverity" : "LOW"
} ,
"exploitabilityScore" : 0.5 ,
"impactScore" : 3.4
}
]
} ,
"weaknesses" : [
2023-07-05 18:00:37 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "NVD-CWE-noinfo"
}
]
} ,
2023-06-13 10:00:30 +00:00
{
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-477"
}
]
}
] ,
2023-07-05 18:00:37 +00:00
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:simatic_net_pc_software:14.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "34A1F08A-1269-44F0-8B10-70A41F9306B2"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:simatic_net_pc_software:15.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "79A56438-47FC-4184-9401-0B859037D0F1"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:simatic_pcs_7:8.2:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "3EEF9BE1-F6E2-4C05-8020-4D7540882464"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "0D25510C-F677-4A98-806C-FF644F11EEC6"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "8.0" ,
"matchCriteriaId" : "D7E53AD8-C669-4E1F-9519-4DED57668766"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinaut_st7sc:*:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "B3C162C7-AC9A-44E3-BAE5-1C0D434F264B"
}
]
}
]
}
] ,
2023-06-13 10:00:30 +00:00
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf" ,
2023-07-05 18:00:37 +00:00
"source" : "productcert@siemens.com" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2023-06-13 10:00:30 +00:00
}
]
}