"id": "CVE-2020-5726",
"sourceIdentifier": "vulnreport@tenable.com",
"published": "2020-03-30T20:15:20.180",
"lastModified": "2020-03-31T17:15:26.887",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the CTI server on port 8888. A remote unauthenticated attacker can invoke the challenge action with a crafted username and discover user passwords."
},
{
"lang": "es",
"value": "La serie Grandstream UCM6200 versiones anteriores a 1.0.20.22, es vulnerable a una inyecci\u00f3n SQL por medio del servidor CTI en el puerto 8888. Un atacante no autenticado remoto puede invocar la acci\u00f3n challenge con un nombre de usuario dise\u00f1ado y detectar las contrase\u00f1as de usuarios."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
},
{
"source": "vulnreport@tenable.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.20.22",
"matchCriteriaId": "F55C1906-9C0D-4479-B545-059329485BCD"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:grandstream:ucm6202:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9864BD0F-BE9C-4F72-AB57-77036699029B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.20.22",
"matchCriteriaId": "2D9A2414-684F-4C61-BCAC-E7967A7BFF2B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:grandstream:ucm6204:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B5A26ABB-8BED-4E61-91AA-ABF1B90CBD81"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.20.22",
"matchCriteriaId": "3164240C-6CAB-4433-8EB3-5F09552A7F4D"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:grandstream:ucm6208:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EA744718-8862-4579-B9CF-E1E8137A02E6"
}
]
}
]
}
],
"references": [
{
"url": "http://packetstormsecurity.com/files/156977/Grandstream-UCM6200-Series-CTI-Interface-SQL-Injection.html",
"source": "vulnreport@tenable.com"
},
{
"url": "https://www.tenable.com/security/research/tra-2020-17",
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}