146 lines
4.0 KiB
JSON
Raw Normal View History

2023-04-24 12:24:31 +02:00
{
"id": "CVE-2020-6774",
"sourceIdentifier": "psirt@bosch.com",
"published": "2020-05-27T17:15:10.113",
"lastModified": "2020-05-29T17:35:22.723",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Improper Access Control in the Kiosk Mode functionality of Bosch Recording Station allows a local unauthenticated attacker to escape from the Kiosk Mode and access the underlying operating system."
},
{
"lang": "es",
"value": "Un Control de Acceso Inapropiado en la funcionalidad Kiosk Mode de Bosch Recording Station, permite a un atacante no autenticado local escapar del Kiosk Mode y acceder al sistema operativo subyacente."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.0,
"impactScore": 6.0
},
{
"source": "psirt@bosch.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.3,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 2.5,
"impactScore": 6.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2
},
"baseSeverity": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-668"
}
]
},
{
"source": "psirt@bosch.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:bosch:recording_station_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "05A6BBEB-8AA1-4DD0-9226-729F30B8685F"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:bosch:recording_station:-:*:*:*:*:*:*:*",
"matchCriteriaId": "167FAB38-08E5-42D0-83B9-9B2990C201EF"
}
]
}
]
}
],
"references": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-363824-BT.html",
"source": "psirt@bosch.com",
"tags": [
"Vendor Advisory"
]
}
]
}