2023-07-11 18:00:45 +00:00
{
"id" : "CVE-2023-28001" ,
"sourceIdentifier" : "psirt@fortinet.com" ,
"published" : "2023-07-11T17:15:12.883" ,
2023-11-07 21:03:21 +00:00
"lastModified" : "2023-11-07T04:10:22.770" ,
"vulnStatus" : "Modified" ,
2023-07-11 18:00:45 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "An insufficient session expiration in Fortinet FortiOS 7.0.0 - 7.0.12 and 7.2.0 - 7.2.4 allows an attacker to execute unauthorized code or commands via reusing the session of a deleted user in the REST API."
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-07-18 22:00:38 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 9.8 ,
"baseSeverity" : "CRITICAL"
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 5.9
} ,
2023-07-11 18:00:45 +00:00
{
2023-11-07 21:03:21 +00:00
"source" : "6abe59d8-c742-4dff-8ce8-9b0ca1073da8" ,
2023-07-11 18:00:45 +00:00
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "HIGH" ,
"privilegesRequired" : "HIGH" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "LOW" ,
"integrityImpact" : "LOW" ,
"availabilityImpact" : "LOW" ,
"baseScore" : 4.1 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 0.7 ,
"impactScore" : 3.4
}
]
} ,
2023-07-18 22:00:38 +00:00
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
2023-11-07 21:03:21 +00:00
"value" : "CWE-613"
}
]
} ,
{
"source" : "6abe59d8-c742-4dff-8ce8-9b0ca1073da8" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
2023-07-18 22:00:38 +00:00
"value" : "CWE-613"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "7.0.0" ,
"versionEndIncluding" : "7.0.12" ,
"matchCriteriaId" : "BA582D59-C740-4AE7-83CA-C09A1D0EDA88"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "7.2.0" ,
"versionEndIncluding" : "7.2.4" ,
"matchCriteriaId" : "4AB643A8-B52F-4D54-B816-28A6401BAA25"
}
]
}
]
}
] ,
2023-07-11 18:00:45 +00:00
"references" : [
{
"url" : "https://fortiguard.com/psirt/FG-IR-23-028" ,
2023-07-18 22:00:38 +00:00
"source" : "psirt@fortinet.com" ,
"tags" : [
"Vendor Advisory"
]
2023-07-11 18:00:45 +00:00
}
]
}