2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2023-1285" ,
"sourceIdentifier" : "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp" ,
"published" : "2023-04-14T03:15:07.003" ,
2023-04-24 16:55:55 +02:00
"lastModified" : "2023-04-24T13:22:28.457" ,
"vulnStatus" : "Analyzed" ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are \"16\" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially crafted packets to any UDP port when GC-ENET-COM is configured as a Modbus TCP Server. The communication resumes only when the power of the main unit is turned off and on or when the GC-ENET-COM is hot-swapped from the main unit.\n"
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-04-24 16:55:55 +02:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "HIGH" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 5.9 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 2.2 ,
"impactScore" : 3.6
} ,
2023-04-24 12:24:31 +02:00
{
"source" : "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.5 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 3.6
}
]
} ,
"weaknesses" : [
2023-04-24 16:55:55 +02:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-362"
}
]
} ,
2023-04-24 12:24:31 +02:00
{
"source" : "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-364"
}
]
}
] ,
2023-04-24 16:55:55 +02:00
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:mitsubishielectric:gc-enet-com_firmware:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "0A0AA732-9C55-45CA-A049-5D8BC40926A5"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:mitsubishielectric:gc-enet-com:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "FB5D1352-A15E-43A5-9CF7-374E4DA7A080"
}
]
}
]
}
] ,
2023-04-24 12:24:31 +02:00
"references" : [
{
"url" : "https://mitsubishielectric.in/fa/cnc-pdf/DoS_in_Ethernet_Communication_Extension_Unit_GC_ENET_COM_of_GOC35_Series.pdf" ,
2023-04-24 16:55:55 +02:00
"source" : "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp" ,
"tags" : [
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
} ,
{
"url" : "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-15" ,
2023-04-24 16:55:55 +02:00
"source" : "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp" ,
"tags" : [
"Third Party Advisory" ,
"US Government Resource"
]
2023-04-24 12:24:31 +02:00
}
]
}