110 lines
3.3 KiB
JSON
Raw Normal View History

{
"id": "CVE-2022-32257",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-03-12T11:15:45.210",
"lastModified": "2024-11-21T07:06:02.340",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (todas las versiones &lt; V3.2). La aplicaci\u00f3n afectada consiste en un servicio web que carece de un control de acceso adecuado para algunos de los endpoints. Esto podr\u00eda provocar un acceso no autorizado a los recursos y potencialmente provocar la ejecuci\u00f3n de c\u00f3digo."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2",
"matchCriteriaId": "BA2839E7-E397-4D69-865B-439F0017D540"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-576771.html",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-576771.html",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}