"id": "CVE-2022-39137",
"sourceIdentifier": "productcert@siemens.com",
"published": "2022-09-13T10:15:10.967",
"lastModified": "2024-11-21T07:17:39.020",
"vulnStatus": "Modified",
"cveTags": [],
2023-04-24 12:24:31 +02:00
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17276)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Parasolid versiones V33.1 (Todas las versiones anteriores a V33.1.262), Parasolid versiones V34.0 (Todas las versiones anteriores a V34.0.252), Parasolid versiones V34.1 (Todas las versiones anteriores a V34.1.242), Parasolid versiones V35.0 (Todas las versiones anteriores a V35.0.161), Simcenter Femap versiones V2022.1 (Todas las versiones anteriores a V2022.1.3), Simcenter Femap versiones V2022.2 (Todas las versiones anteriores a V2022.2.2). La aplicaci\u00f3n afectada es vulnerable a una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado cuando son analizados archivos X_T. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-17276)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
2023-04-24 12:24:31 +02:00
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
2023-04-24 12:24:31 +02:00
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
2023-04-24 12:24:31 +02:00
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022.1",
"versionEndExcluding": "2022.1.3",
"matchCriteriaId": "55A01C08-1B67-4D81-8730-9ED534E37F7F"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022.2",
"versionEndExcluding": "2022.2.2",
"matchCriteriaId": "7CF06743-FC11-46E1-BD60-D9F6F514E52C"
}
]
}
]
},
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "33.1",
"versionEndExcluding": "33.1.262",
"matchCriteriaId": "9C9495DA-A41E-4B6B-BD27-B5132F38B7D4"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "34.0",
"versionEndExcluding": "34.0.252",
"matchCriteriaId": "F0D9079D-6138-4602-A982-9BC4ECBC35E7"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "34.1",
"versionEndExcluding": "34.1.242",
"matchCriteriaId": "4C486991-A1C0-4815-AAD6-163464D711AA"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "35.0",
"versionEndExcluding": "35.0.161",
"matchCriteriaId": "4412F05F-EBA8-439D-868A-D14FC739E255"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}