2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-3156" ,
"sourceIdentifier" : "PSIRT@rockwellautomation.com" ,
"published" : "2022-12-27T19:15:10.357" ,
2023-11-07 21:03:21 +00:00
"lastModified" : "2023-11-07T03:50:51.807" ,
"vulnStatus" : "Modified" ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
2023-11-07 21:03:21 +00:00
"value" : "A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software.\u00a0 Users are granted elevated permissions on certain product services when the software is installed.\u00a0Due to \nthis misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.\n\n \n\n\n"
2023-04-24 12:24:31 +02:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
} ,
{
2023-11-07 21:03:21 +00:00
"source" : "b73dd486-f505-4403-b634-40b078b177f0" ,
2023-04-24 12:24:31 +02:00
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-287"
}
]
} ,
{
2023-11-07 21:03:21 +00:00
"source" : "b73dd486-f505-4403-b634-40b078b177f0" ,
2023-04-24 12:24:31 +02:00
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-287"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:rockwellautomation:studio_5000_logix_emulate:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "20.011" ,
"versionEndExcluding" : "34.00" ,
"matchCriteriaId" : "FB9EB8A2-A2F2-45A4-923E-2E40BDF16F76"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846" ,
"source" : "PSIRT@rockwellautomation.com" ,
"tags" : [
"Vendor Advisory"
]
}
]
}