2025-03-12 17:03:50 +00:00
{
"id" : "CVE-2025-0813" ,
"sourceIdentifier" : "cybersecurity@se.com" ,
"published" : "2025-03-12T16:15:20.183" ,
"lastModified" : "2025-03-12T16:15:20.183" ,
2025-03-16 03:03:50 +00:00
"vulnStatus" : "Awaiting Analysis" ,
2025-03-12 17:03:50 +00:00
"cveTags" : [ ] ,
"descriptions" : [
{
"lang" : "en" ,
"value" : "CWE-287: Improper Authentication vulnerability exists that could cause an Authentication Bypass when an\nunauthorized user without permission rights has physical access to the EPAS-UI computer and is able to\nreboot the workstation and interrupt the normal boot process."
2025-03-16 03:03:50 +00:00
} ,
{
"lang" : "es" ,
"value" : "CWE-287: Existe una vulnerabilidad de autenticaci\u00f3n incorrecta que podr\u00eda provocar una omisi\u00f3n de autenticaci\u00f3n cuando un usuario no autorizado sin derechos de permiso tiene acceso f\u00edsico a la computadora EPAS-UI y puede reiniciar la estaci\u00f3n de trabajo e interrumpir el proceso de arranque normal."
2025-03-12 17:03:50 +00:00
}
] ,
"metrics" : {
"cvssMetricV40" : [
{
"source" : "cybersecurity@se.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "4.0" ,
"vectorString" : "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X" ,
"baseScore" : 7.0 ,
"baseSeverity" : "HIGH" ,
"attackVector" : "PHYSICAL" ,
"attackComplexity" : "LOW" ,
"attackRequirements" : "NONE" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"vulnConfidentialityImpact" : "HIGH" ,
"vulnIntegrityImpact" : "HIGH" ,
"vulnAvailabilityImpact" : "HIGH" ,
"subConfidentialityImpact" : "NONE" ,
"subIntegrityImpact" : "NONE" ,
"subAvailabilityImpact" : "NONE" ,
"exploitMaturity" : "NOT_DEFINED" ,
"confidentialityRequirement" : "NOT_DEFINED" ,
"integrityRequirement" : "NOT_DEFINED" ,
"availabilityRequirement" : "NOT_DEFINED" ,
"modifiedAttackVector" : "NOT_DEFINED" ,
"modifiedAttackComplexity" : "NOT_DEFINED" ,
"modifiedAttackRequirements" : "NOT_DEFINED" ,
"modifiedPrivilegesRequired" : "NOT_DEFINED" ,
"modifiedUserInteraction" : "NOT_DEFINED" ,
"modifiedVulnConfidentialityImpact" : "NOT_DEFINED" ,
"modifiedVulnIntegrityImpact" : "NOT_DEFINED" ,
"modifiedVulnAvailabilityImpact" : "NOT_DEFINED" ,
"modifiedSubConfidentialityImpact" : "NOT_DEFINED" ,
"modifiedSubIntegrityImpact" : "NOT_DEFINED" ,
"modifiedSubAvailabilityImpact" : "NOT_DEFINED" ,
"Safety" : "NOT_DEFINED" ,
"Automatable" : "NOT_DEFINED" ,
"Recovery" : "NOT_DEFINED" ,
"valueDensity" : "NOT_DEFINED" ,
"vulnerabilityResponseEffort" : "NOT_DEFINED" ,
"providerUrgency" : "NOT_DEFINED"
}
}
] ,
"cvssMetricV31" : [
{
"source" : "cybersecurity@se.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 6.8 ,
"baseSeverity" : "MEDIUM" ,
"attackVector" : "PHYSICAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH"
} ,
"exploitabilityScore" : 0.9 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "cybersecurity@se.com" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-287"
}
]
}
] ,
"references" : [
{
"url" : "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-070-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-070-02.pdf" ,
"source" : "cybersecurity@se.com"
}
]
}