2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-27871" ,
"sourceIdentifier" : "psirt@autodesk.com" ,
"published" : "2022-06-21T15:15:08.863" ,
2024-12-08 03:06:42 +00:00
"lastModified" : "2024-11-21T06:56:22.103" ,
"vulnStatus" : "Modified" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "Autodesk AutoCAD product suite, Revit, Design Review and Navisworks releases using PDFTron prior to 9.1.17 version may be used to write beyond the allocated buffer while parsing PDF files. This vulnerability may be exploited to execute arbitrary code."
} ,
{
"lang" : "es" ,
"value" : "Las versiones del paquete de productos AutoCAD, Revit, Design Review y Navisworks que usan PDFTron versiones anteriores a 9.1.17, pueden escribir m\u00e1s all\u00e1 del b\u00fafer asignado mientras analizan los archivos PDF. Esta vulnerabilidad puede ser explotada para ejecutar c\u00f3digo arbitrario"
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" ,
2024-12-08 03:06:42 +00:00
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "REQUIRED" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "HIGH"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:N/AC:M/Au:N/C:P/I:P/A:P" ,
2024-12-08 03:06:42 +00:00
"baseScore" : 6.8 ,
2023-04-24 12:24:31 +02:00
"accessVector" : "NETWORK" ,
"accessComplexity" : "MEDIUM" ,
"authentication" : "NONE" ,
"confidentialityImpact" : "PARTIAL" ,
"integrityImpact" : "PARTIAL" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "PARTIAL"
2023-04-24 12:24:31 +02:00
} ,
"baseSeverity" : "MEDIUM" ,
"exploitabilityScore" : 8.6 ,
"impactScore" : 6.4 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : true
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-770"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:3ds_max:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "88A89032-1BA1-4657-98F6-E2ECB19BB4E6"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:3ds_max:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "887292AA-AC0F-4931-B55B-5FAAA127E3D0"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:advance_steel:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "963B02A8-97DE-4C10-9AE1-3DA4FBC9AF9F"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:advance_steel:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "8C4543D1-94E4-4470-91BF-6F3141FD9DAE"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:advance_steel:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "AB44E46E-C1FF-4642-9F0D-FEE599F12508"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:advance_steel:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "FABA4668-B759-4EF8-B4F7-DD824A5BD38B"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "411DC826-735A-4BEB-84BE-9250F97F612E"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "E30E2562-D38E-4764-874E-5B2FCF5639E5"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "88B2C295-D091-4C1D-8285-4309967707BC"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "EACE09F2-A323-4E4B-9A35-4EBAE3864E6C"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad:2022:*:*:*:*:macos:*:*" ,
"matchCriteriaId" : "68FC54D1-B4FC-404E-9742-72F8340FE3C7"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_architecture:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "9275E76C-2A79-462A-A9D3-D0B6BBCDD0CC"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_architecture:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "B7DFA12E-48C5-47B9-BD9F-1AFACBF4E1EA"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_architecture:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "535A5D39-1C82-4301-9E5B-C9E0D75F38B9"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_architecture:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "316615EC-BC9F-4B6A-8163-EBECC480EFDE"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_civil_3d:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "AB3A878B-2142-404F-BCF4-BB508674C6C4"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_civil_3d:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "64F2EC88-168D-4DD1-9ADA-3F9FA60D6E35"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_civil_3d:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "5D73C803-7567-4C1D-B62A-C3C52369022D"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_civil_3d:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "C5F77B03-3221-4564-B4FF-7BF7EEC1C5B6"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_electrical:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "A10DE5AF-1718-4899-9238-CFFDC72D05B7"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_electrical:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "E388264D-D2D4-4BE4-9097-8F547D73ABE5"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_electrical:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "16611BAA-C200-4C8B-823F-1AB95F5E1317"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_electrical:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "E2DC5114-48D2-4D85-8E80-B4BCB0FD78F5"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_lt:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "03682B7E-1CF1-4456-A51F-A6ADFC177935"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_lt:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "371C5F60-4959-40C7-93E1-A01510A95115"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_lt:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "D83FB4C7-B374-4907-8E2B-EEE61C8339E7"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_lt:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "601676EC-2EB4-45D0-B1AE-0980CBD68770"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_lt:2022:*:*:*:*:macos:*:*" ,
"matchCriteriaId" : "4A2EF334-E4E2-40DA-BD51-B74EE1E0ACCF"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_map_3d:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "04E05510-B21B-4DDD-88D7-CEB8963E1AFB"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_map_3d:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "D4CD010A-FDBC-40F9-95AC-0CD8388B85D1"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_map_3d:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "FC99E0F3-AA11-4390-A7C0-5BBFCDA94E3F"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_map_3d:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "33AA60CF-611C-45FC-92F8-7517D87B1645"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_mechanical:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "19255CEC-6161-4D44-B87E-52E86DF4FBA7"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_mechanical:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "7147F378-DFB0-48A8-8B05-8777E1CC7F90"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_mechanical:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "3B5C858C-4A01-4916-BE3E-B9056D67CF5F"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_mechanical:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "7EB83A4A-D4C2-4509-BD49-15B9BBC7BF97"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_mep:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "3F608B1C-BA96-4EA8-A540-83870262CBC1"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_mep:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "7CFAAD19-6248-42CB-B177-EC2E5141A953"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_mep:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "1C52D90B-578B-4281-BF0E-B7CDA425ED05"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_mep:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "4C8AD4F3-AA82-49F5-A18A-85127FDB8B95"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_plant_3d:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "4E536B0D-4C95-4589-981A-2F8A6C4B44DC"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_plant_3d:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "3FBDD3AC-FA00-462F-AA13-5A75B5D50689"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_plant_3d:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "73E2E9E8-2269-4729-8D8F-3C26974F5FD2"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:autocad_plant_3d:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "452A1A75-C59A-43AB-9C43-BA49EB95C39C"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:design_review:2018:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "213232B9-A40B-436D-A66A-B65C49D59BE6"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:navisworks:2019:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "F8EB8353-CA0F-4B38-9427-56C845696A7D"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:navisworks:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "3B3A9D11-51D7-4384-A6CF-B1AE46625E66"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:navisworks:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "8694D891-A923-4B62-A508-77E6EBC54646"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:revit:2020:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "8A183FC7-49B7-4475-A580-E87B68690997"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:revit:2021:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "E9CFAE69-D0D3-4850-8752-DD2DC3FF51CA"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:revit:2022:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "70FD96A0-AC16-4E51-B4C1-6BB14C2D905A"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0011" ,
"source" : "psirt@autodesk.com" ,
"tags" : [
"Vendor Advisory"
]
2024-12-08 03:06:42 +00:00
} ,
{
"url" : "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0011" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}