55 lines
1.6 KiB
JSON
Raw Normal View History

{
"id": "CVE-2023-4516",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2023-09-14T09:15:08.610",
"lastModified": "2023-09-14T13:01:03.610",
"vulnStatus": "Awaiting Analysis",
"descriptions": [
{
"lang": "en",
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "cybersecurity@se.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-255-01.pdf",
"source": "cybersecurity@se.com"
}
]
}