2023-11-23 09:04:08 +00:00
{
"id" : "CVE-2023-44289" ,
"sourceIdentifier" : "security_alert@emc.com" ,
"published" : "2023-11-23T07:15:46.950" ,
2023-11-30 07:00:22 +00:00
"lastModified" : "2023-11-30T05:04:54.330" ,
"vulnStatus" : "Analyzed" ,
2023-11-23 09:04:08 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "\nDell Command | Configure versions prior to 4.11.0, contain an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability while repairing/changing installation, leading to privilege escalation.\n\n"
2023-11-24 17:00:21 +00:00
} ,
{
"lang" : "es" ,
"value" : "Dell Command | Configure las versiones anteriores a la 4.11.0 contienen una vulnerabilidad de control de acceso inadecuado. Un usuario est\u00e1ndar malicioso local podr\u00eda explotar esta vulnerabilidad mientras repara/cambia la instalaci\u00f3n, lo que provocar\u00eda una escalada de privilegios."
2023-11-23 09:04:08 +00:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-11-30 07:00:22 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
} ,
2023-11-23 09:04:08 +00:00
{
"source" : "security_alert@emc.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "REQUIRED" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.3 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.3 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
2023-11-30 07:00:22 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "NVD-CWE-Other"
}
]
} ,
2023-11-23 09:04:08 +00:00
{
"source" : "security_alert@emc.com" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-284"
}
]
}
] ,
2023-11-30 07:00:22 +00:00
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:dell:command\\|configure:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "4.11.0" ,
"matchCriteriaId" : "9B2C8ECB-DF22-4790-B6AA-EC705851AC70"
}
]
}
]
}
] ,
2023-11-23 09:04:08 +00:00
"references" : [
{
"url" : "https://www.dell.com/support/kbdoc/en-us/000218628/dsa-2023-390-security-update-for-dell-command-configure-and-dell-command-monitor-vulnerabilities" ,
2023-11-30 07:00:22 +00:00
"source" : "security_alert@emc.com" ,
"tags" : [
"Vendor Advisory"
]
2023-11-23 09:04:08 +00:00
}
]
}