2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-24290" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2022-05-20T13:15:14.737" ,
2024-11-23 15:12:23 +00:00
"lastModified" : "2024-11-21T06:50:06.057" ,
"vulnStatus" : "Modified" ,
2024-12-08 03:06:42 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions), Teamcenter V13.2 (All versions < V13.2.0.8), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash."
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en Teamcenter V12.4 (Todas las versiones anteriores a V12.4.0.13), Teamcenter V13.0 (Todas las versiones anteriores a V13.0.0.9), Teamcenter V13.1 (Todas las versiones), Teamcenter V13.2 (Todas las versiones anteriores a V13.2.0.8), Teamcenter V13.3 (Todas las versiones anteriores a V13.3.0.3), Teamcenter V14.0 (Todas las versiones anteriores a V14.0.0.2). El binario tcserver.exe de las aplicaciones afectadas es vulnerable a una condici\u00f3n de desbordamiento de pila durante el an\u00e1lisis de la entrada del usuario que puede hacer que el binario se bloquee"
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" ,
2024-11-23 15:12:23 +00:00
"baseScore" : 7.5 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "NONE" ,
2024-11-23 15:12:23 +00:00
"availabilityImpact" : "HIGH"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 3.6
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:N/AC:L/Au:N/C:N/I:N/A:P" ,
2024-11-23 15:12:23 +00:00
"baseScore" : 5.0 ,
2023-04-24 12:24:31 +02:00
"accessVector" : "NETWORK" ,
"accessComplexity" : "LOW" ,
"authentication" : "NONE" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "NONE" ,
2024-11-23 15:12:23 +00:00
"availabilityImpact" : "PARTIAL"
2023-04-24 12:24:31 +02:00
} ,
"baseSeverity" : "MEDIUM" ,
"exploitabilityScore" : 10.0 ,
"impactScore" : 2.9 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : false
}
]
} ,
"weaknesses" : [
{
"source" : "productcert@siemens.com" ,
2024-12-15 03:03:56 +00:00
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"description" : [
{
"lang" : "en" ,
"value" : "CWE-121"
}
]
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-787"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "12.4" ,
"versionEndExcluding" : "12.4.0.13" ,
"matchCriteriaId" : "CA684297-D33B-4E81-A19F-29514EB409A0"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "13.0" ,
"versionEndExcluding" : "13.0.0.9" ,
"matchCriteriaId" : "C0EDF96B-DF5B-4A9E-A70E-FD3EEE8067CD"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "13.1" ,
"versionEndExcluding" : "13.1.0.9" ,
"matchCriteriaId" : "80958809-7B4E-4B17-8438-1AA0F5960F90"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "13.2" ,
"versionEndExcluding" : "13.2.0.8" ,
"matchCriteriaId" : "18D62450-7CF5-4DE6-BDA2-24AF6CA93D74"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "13.3" ,
"versionEndExcluding" : "13.3.0.3" ,
"matchCriteriaId" : "704B0DB9-516D-4CDE-89AE-D36100B3B84A"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter:14.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "81AC6B3C-5221-4F9A-B495-737910347408"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf" ,
"source" : "productcert@siemens.com" ,
"tags" : [
"Mitigation" ,
"Patch" ,
"Vendor Advisory"
]
2024-11-23 15:12:23 +00:00
} ,
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Mitigation" ,
"Patch" ,
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}