2024-09-10 12:03:19 +00:00
{
"id" : "CVE-2024-42345" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2024-09-10T10:15:12.433" ,
2024-09-10 14:03:33 +00:00
"lastModified" : "2024-09-10T12:09:50.377" ,
"vulnStatus" : "Awaiting Analysis" ,
2024-09-10 12:03:19 +00:00
"cveTags" : [ ] ,
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP2). The affected application does not properly handle user session establishment and invalidation. This could allow a remote attacker to circumvent the additional multi factor authentication for user session establishment."
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (todas las versiones anteriores a V3.2 SP2). La aplicaci\u00f3n afectada no gestiona correctamente el establecimiento y la invalidaci\u00f3n de sesiones de usuario. Esto podr\u00eda permitir que un atacante remoto eluda la autenticaci\u00f3n multifactor adicional para el establecimiento de sesiones de usuario."
}
] ,
"metrics" : {
"cvssMetricV40" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "4.0" ,
"vectorString" : "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"attackRequirements" : "NONE" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"vulnerableSystemConfidentiality" : "NONE" ,
"vulnerableSystemIntegrity" : "LOW" ,
"vulnerableSystemAvailability" : "NONE" ,
"subsequentSystemConfidentiality" : "NONE" ,
"subsequentSystemIntegrity" : "NONE" ,
"subsequentSystemAvailability" : "NONE" ,
"exploitMaturity" : "NOT_DEFINED" ,
"confidentialityRequirements" : "NOT_DEFINED" ,
"integrityRequirements" : "NOT_DEFINED" ,
"availabilityRequirements" : "NOT_DEFINED" ,
"modifiedAttackVector" : "NOT_DEFINED" ,
"modifiedAttackComplexity" : "NOT_DEFINED" ,
"modifiedAttackRequirements" : "NOT_DEFINED" ,
"modifiedPrivilegesRequired" : "NOT_DEFINED" ,
"modifiedUserInteraction" : "NOT_DEFINED" ,
"modifiedVulnerableSystemConfidentiality" : "NOT_DEFINED" ,
"modifiedVulnerableSystemIntegrity" : "NOT_DEFINED" ,
"modifiedVulnerableSystemAvailability" : "NOT_DEFINED" ,
"modifiedSubsequentSystemConfidentiality" : "NOT_DEFINED" ,
"modifiedSubsequentSystemIntegrity" : "NOT_DEFINED" ,
"modifiedSubsequentSystemAvailability" : "NOT_DEFINED" ,
"safety" : "NOT_DEFINED" ,
"automatable" : "NOT_DEFINED" ,
"recovery" : "NOT_DEFINED" ,
"valueDensity" : "NOT_DEFINED" ,
"vulnerabilityResponseEffort" : "NOT_DEFINED" ,
"providerUrgency" : "NOT_DEFINED" ,
"baseScore" : 5.3 ,
"baseSeverity" : "MEDIUM"
}
}
] ,
"cvssMetricV31" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "LOW" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 4.3 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 1.4
}
]
} ,
"weaknesses" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-384"
}
]
}
] ,
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/html/ssa-869574.html" ,
"source" : "productcert@siemens.com"
}
]
}