"id": "CVE-2022-41668",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2022-11-04T12:15:20.540",
"lastModified": "2022-11-05T02:02:55.973",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior)."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.0,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.0,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "cybersecurity@se.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-704"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.3",
"matchCriteriaId": "5705916B-E189-4314-AD32-C8D42991DFA2"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:*:*:*:*:*:*:*",
"matchCriteriaId": "5585436E-9363-4730-9AF5-CE705093E664"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:hf1:*:*:*:*:*:*",
"matchCriteriaId": "1495D2CA-263C-4B9F-9C4F-A1DCA574743E"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.3",
"matchCriteriaId": "297C4149-AA1F-4033-BD74-0FB908783399"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:3.3:*:*:*:*:*:*:*",
"matchCriteriaId": "5B593005-BB3F-439A-AF38-F31AFEF6FCB9"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:3.3:hf1:*:*:*:*:*:*",
"matchCriteriaId": "D3D36B2C-AA16-4E42-90AF-DE40D6527D23"
}
]
}
]
}
],
"references": [
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-284-01/",
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}