2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2019-19295" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2020-03-10T20:15:19.507" ,
2024-01-09 11:00:29 +00:00
"lastModified" : "2024-01-09T10:15:12.627" ,
2023-04-24 12:24:31 +02:00
"vulnStatus" : "Modified" ,
"descriptions" : [
{
"lang" : "en" ,
2024-01-09 11:00:29 +00:00
"value" : "A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of\nsecurity-relevant activities in its XML-based communication protocol\nas provided by default on ports 5444/tcp and 5440/tcp.\nAn authenticated remote attacker could exploit this vulnerability to\nperform covert actions that are not visible in the application log."
2023-04-24 12:24:31 +02:00
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en Central Control Server (CCS) (Todas las versiones anteriores a V1.5.0). El Servidor de Control Center (CCS) no aplica el registro de actividades relevantes para la seguridad en su protocolo de comunicaci\u00f3n basado en XML, tal y como se proporciona por defecto en los puertos 5444/tcp y 5440/tcp. Un atacante remoto autenticado podr\u00eda explotar esta vulnerabilidad para realizar acciones encubiertas que no son visibles en el registro de la aplicaci\u00f3n"
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "LOW" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 4.3 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 1.4
2024-01-09 11:00:29 +00:00
} ,
{
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "LOW" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 4.3 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 1.4
2023-04-24 12:24:31 +02:00
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:N/AC:L/Au:S/C:N/I:P/A:N" ,
"accessVector" : "NETWORK" ,
"accessComplexity" : "LOW" ,
"authentication" : "SINGLE" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "PARTIAL" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 4.0
} ,
"baseSeverity" : "MEDIUM" ,
"exploitabilityScore" : 8.0 ,
"impactScore" : 2.9 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : false
}
]
} ,
"weaknesses" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-778"
}
]
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "NVD-CWE-Other"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "16668E9A-2D0A-425E-87F4-18CFC50551D3"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "0F21BB6D-BFE0-4B69-97F2-1A871A390B1E"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf" ,
"source" : "productcert@siemens.com"
} ,
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf" ,
"source" : "productcert@siemens.com" ,
"tags" : [
"Vendor Advisory"
]
}
]
}